Shop Pressure Instruments
Pressure gauges
A gauge reads pressure at the point it is fitted, with no wiring and nothing to configure. Because it works whether or not your control system does, a gauge stays useful during a fault, a power cut or a commissioning check.
Analogue pressure gauges
Suitable for: Liquids · Gases · Steam (with a siphon)
Analogue gauges are built around a Bourdon tube, a flattened metal tube curved into a C or a helix and sealed at one end. Pressure inside the tube pushes its squashed cross-section back towards round, which makes the tube try to straighten. A geared linkage magnifies that tiny movement and swings the pointer. The same mechanism reads vacuum, and for very low pressures a capsule element, two thin diaphragms welded together, is used instead because it flexes further for the same pressure.
We hold dial sizes from 50 mm to 100 mm in stock, in dry and glycerine-filled versions, with a choice of case materials, process connections and ranges from vacuum to 700 bar. Glycerine filling damps the pointer where there is vibration or pulsation, which is the single most common cause of gauge failure.
All our analogue pressure gauges are made in New Zealand by Teltherm Instruments Ltd, the only New Zealand manufacturer of Bourdon tube pressure gauges. Being made here rather than imported has a practical consequence: a custom range, dial size, process connection or scale is a manufacturing instruction rather than a special order, and a replacement does not wait on a shipment.
Digital pressure gauges
Suitable for: Liquids · Gases · Steam (with a siphon)
Digital pressure gauges put an electronic sensor behind a digital display. You get finer resolution than a dial can show, a much wider usable span from one instrument, and features a mechanical gauge cannot offer: peak hold, tare, selectable units, adjustable damping and, on some models, logging. Battery-powered versions are a practical field reference for checking installed gauges without taking them off the plant.


Differential pressure and manometers
Some of the most useful pressure readings are not pressures at all, but the difference between two of them. Differential instruments are how you measure filter condition, fan and duct performance, room pressurisation and liquid level in a closed tank.
Differential pressure gauges
Suitable for: Gases (air and clean gases) · Liquids (compatible models)
A differential pressure gauge has two process connections and displays the difference between them. The common low-pressure design uses a diaphragm between two chambers, with the diaphragm’s movement transferred magnetically to the pointer, so there is no mechanical seal to leak. These gauges are the standard way to watch a filter: a new filter shows a low, steady reading, and a rising reading tells you it is loading up and due for change.
Typical uses are filter monitoring, fan and blower performance, duct and cleanroom pressurisation, and airflow proving. Ranges start very low, often in pascals or inches of water gauge, because the differences involved are small.
Manometers
Suitable for: Gases (air and clean gases)
A manometer measures low pressure and differential pressure directly. Liquid column types balance the pressure against a column of fluid in a tube, and you read the height difference on a scale, which needs no power or calibration adjustment. Digital manometers do the same job electronically, with a wider range, a faster response and the ability to record readings.
Manometers are the usual tool for commissioning and balancing air systems, checking burner gas pressure, testing for duct leakage and proving room pressure differentials.
Pitot tubes and air velocity
Suitable for: Gases (air)
Pair a manometer with a pitot tube and you can measure air velocity in a duct. The pitot tube senses the impact pressure facing the airflow and the static pressure at the duct wall; the difference between the two, the velocity pressure, converts to velocity and then to volumetric flow once the duct area is known. It remains the reference method for duct traverses.
Transmitters and switches
When the reading has to leave the instrument, you need either a transmitter, which reports pressure continuously, or a switch, which acts at one point.
Pressure transmitters
Suitable for: Liquids · Gases · Steam (with a siphon)
A pressure transmitter turns pressure into a signal your PLC, logger or SCADA system can read, most often 4–20 mA, sometimes a voltage output or a digital protocol. Inside, a diaphragm flexes under pressure and a sensing element converts that movement into an electrical change: strain gauge elements bonded to the diaphragm change resistance, silicon piezoresistive sensors do the same in a much smaller package, and capacitive sensors read the change in the gap between the diaphragm and a fixed plate. Capacitive sensors hold their accuracy best at low pressures and for differential measurement.
Transmitters are made for gauge, absolute and differential pressure, and submersible versions on vented cable are the standard way to measure the depth of water in a tank, bore or reservoir.
Pressure switches
Suitable for: Liquids · Gases · Steam (with a siphon)
A pressure switch watches for one pressure and does one thing when it is reached. As pressure crosses the set point, the switch changes the state of its contacts to raise an alarm, start or stop a pump or compressor, or trip a process. Mechanical switches use a diaphragm or piston acting against a spring; electronic switches use a pressure sensor and set points you enter on a display, which makes them easier to adjust and repeat across several machines.
The figure to check when selecting a switch is the deadband, sometimes called the differential: the gap between the pressure that operates the switch and the pressure that resets it. Too narrow and the switch chatters, too wide and the process swings.


Fittings and instrument protection
Most pressure instruments that fail early are not faulty; they have been installed without the fitting that would have protected them. These are the parts that make the difference.
Siphons and pigtails
Suitable for: Steam · Hot liquids
A siphon is a loop or coil of pipe fitted between the process and the gauge. Condensate collects in the loop and forms a permanent water barrier, so live steam never reaches the measuring element. A pigtail is the coiled version of the same idea. Fitting one is not optional on steam service; without it the element is cooked and the gauge reads low within months.
Snubbers and damping
Suitable for: Liquids · Gases
A snubber is a restrictor fitted at the gauge inlet that slows how quickly pressure can reach the element. It flattens the pulsation from a reciprocating pump or compressor, so the pointer sits still and the movement stops wearing. Glycerine filling does a similar job inside the gauge, and the two are often used together on hard-working plant.
Isolation valves and shut-offs
Suitable for: Liquids · Gases · Steam
A shut-off or needle valve under the gauge lets you isolate the instrument for removal, testing or replacement without draining or shutting down the line. On systems that are tested regularly, a test point fitting is worth adding as well, so a reference gauge can be connected without breaking the joint.
Diaphragm seals
Suitable for: Liquids (viscous, corrosive, crystallising or hygienic)
A diaphragm seal, also called a chemical seal, separates the instrument from the process. A flexible diaphragm faces the process and a fill fluid behind it carries the pressure through to the instrument, so the process cannot reach the measuring element or block the port. Seals are used on corrosive and viscous media, on products that crystallise, and in food and pharmaceutical plants where the connection has to be cleanable.
Calibrators, test kits and calibration
Pressure instruments drift, and vibration and pulsation make them drift faster. Checking them is either something you do yourself with the right equipment, or something you send to us.
Pressure calibrators
Suitable for: Liquids (hydraulic) · Gases (pneumatic)
A pressure calibrator combines an accurate reference reading with a way of generating the pressure to test against. Hand pumps and comparison test pumps supply the pressure, hydraulic for high ranges and pneumatic for low ranges and gas service, while the calibrator displays what that pressure actually is. More capable units generate and hold pressure automatically, read the instrument’s own 4–20 mA output at the same time, and store the results for a report.
Backflow test kits
Suitable for: Liquids (water)
Backflow prevention devices protect a drinking water supply from contamination, and testable devices have to be verified on a set schedule by a registered tester. A backflow test kit is the differential pressure gauge and hose set used to carry out that test. We supply the kits and we calibrate them, which is a requirement for the test results to stand.
Accredited pressure calibration
Our pressure calibration is accredited by IANZ to ISO/IEC 17025, and in 1980 we became the first pressure laboratory in New Zealand to be certified by Telarc for pressure calibration. We calibrate analogue and digital gauges, transducers and transmitters, and differential and low-pressure instruments, in our Christchurch laboratory or on your site. We also repair and adjust many of the instruments we certify. See Calibration Lab for more.

Choosing a pressure instrument
Two questions settle most of the selection: what kind of pressure, and who needs to see it.
Gauge, absolute or differential?
- Gauge pressure is measured against the surrounding air, so an instrument open to atmosphere reads zero. It is what almost every process gauge, switch and transmitter measures.
- Absolute pressure is measured against a sealed vacuum reference inside the instrument, so it reads about 1013 mbar when open to air at sea level. Use it when the reading must not move with the weather, such as in vacuum work and vapour pressure measurement.
- Differential pressure is the difference between two connections. Use it for filters, fans, ducts, room pressurisation and level in a closed vessel.
What we will ask you
- the working pressure and the highest pressure the instrument could ever see
- the medium, and whether it is hot, corrosive, viscous or has to stay clean
- the process connection, thread form and mounting position
- whether the reading is local only, or has to reach a control system
- whether there is vibration or pulsation at the mounting point
- hazardous area, potable water and certification requirements.
Which instrument suits the job?
| Instrument | Liquids | Gases | Steam | What you get |
|---|---|---|---|---|
| Analogue gauge | ✓ | ✓ | ✓ (with a siphon) | Local reading, no power |
| Digital gauge | ✓ | ✓ | ✓ (with a siphon) | Local reading, extra functions |
| Differential gauge | Some models | ✓ | – | Difference between two points |
| Manometer | – | ✓ | – | Low pressure and differential |
| Pressure transmitter | ✓ | ✓ | ✓ (with a siphon) | Continuous signal |
| Pressure switch | ✓ | ✓ | ✓ (with a siphon) | Action at one set point |
| Diaphragm seal | ✓ | ✓ | – | Protects the instrument |
| Pressure calibrator | ✓ (hydraulic) | ✓ (pneumatic) | – | Reference reading for testing |
Frequently asked questions
Are your pressure gauges made in New Zealand?
Yes. All our analogue pressure gauges are manufactured by Teltherm Instruments Ltd, the only New Zealand manufacturer of Bourdon tube pressure gauges. Custom ranges, dial sizes, process connections and scales can be made to order.
Why does my pressure gauge keep failing?
Vibration and pulsation are the usual causes. A reciprocating pump or compressor works the movement thousands of times a minute until it wears out. Fitting a snubber at the inlet, choosing a glycerine-filled gauge, or both, usually fixes it. On steam, an early failure normally means no siphon was fitted.
Why is my filter differential gauge reading zero?
Either the filter is genuinely clean, or one of the two sensing lines is blocked or disconnected. Check both connections before replacing the gauge, because a blocked high-pressure line gives the same reading as a perfect filter.
What size dial should I choose?
Choose by reading distance and space. A 50 mm or 63 mm dial suits panel and machine mounting where you are close to it, and a 100 mm dial is easier to read across a plant room. Choose the range so the normal working pressure sits near the middle of the scale.
Do you calibrate backflow test kits?
Yes. We calibrate backflow test kits, and we supply them. Testable backflow prevention devices have to be verified on a set schedule, and the test kit itself must hold a current calibration for those results to stand.
How often should pressure instruments be calibrated?
Every 12 months is the usual interval unless your quality system or equipment documentation sets a different one. Calibrate sooner if the instrument has been over-pressured, dropped, or if you have lost confidence in the reading.
Can you calibrate our gauges on site?
Yes, on request. We recommend laboratory calibration where the instrument can be removed, because our full reference equipment and spare parts are on hand and we can adjust or repair at the same time.