Analytics and Monitoring

This part of our range answers questions about the environment your people and products are in: what is in the air, what is in the water, how loud it is, how bright it is, and what the numbers did overnight when nobody was watching. It covers gas detection, combustion analysis, data logging, environmental and workplace measurement, and the calibrators used to check other instruments.

Shop Analytics & Monitoring


Gas detection and combustion analysis


Gas hazards are invisible, and several of the worst ones give no warning at all: no smell, no irritation, no time to react. Detection equipment is what turns that into something you can act on.

Portable and personal gas detectors

Measures: Toxic gases · Combustible gases · Oxygen

A personal monitor is clipped to the worker and alarms where they are, which is the only place the reading matters. Single-gas units cover one known hazard, typically carbon monoxide or hydrogen sulphide. Multi-gas units cover the standard confined-space set, usually oxygen, combustibles, carbon monoxide and hydrogen sulphide, in one instrument. The oxygen channel is there as much for enrichment and depletion as for the gas itself: a space that has been purged with nitrogen will not smell any different.

Portable detectors are also used for leak surveys, pre-entry checks, confined space work and emergency response. Look at the pump or diffusion option, the alarm types, whether the unit logs its readings, and how the bump test and calibration are done.

Fixed gas detectors and transmitters

Measures: Toxic gases · Combustible gases · Oxygen · Refrigerants

A fixed detector watches one location continuously and reports to a controller, PLC or building management system, usually on 4–20 mA or a digital protocol. Detector placement is what makes or breaks the system, and it follows the gas: gases heavier than air, such as LPG and refrigerants, are detected low down, and lighter gases, such as methane and hydrogen, near the ceiling. Plant rooms, cool stores, boiler houses, workshops and carparks are the common installations.

Which sensor detects which gas

Measures: Toxic gases · Combustible gases · VOCs · Refrigerants

The sensor inside decides what the instrument can see and how it must be maintained. Electrochemical cells react with the target gas at an electrode and produce a current proportional to the concentration; they are the standard for toxic gases and oxygen, and they are consumable, with a life measured in years. Catalytic bead sensors burn combustible gas on a heated catalyst and detect the resulting temperature change; they need oxygen present and can be poisoned by silicones, so they need regular calibration. Infrared sensors measure how much infrared light the gas absorbs, so nothing reacts and nothing is consumed, which suits hydrocarbons, carbon dioxide and refrigerants. Photoionisation detectors use ultraviolet light to ionise molecules and are the tool for volatile organic compounds at low concentrations.

Combustion and flue gas analysers

Measures: Oxygen · Carbon monoxide · Combustion efficiency

A flue gas analyser samples the exhaust from a burner, boiler or engine and reports oxygen, carbon monoxide, temperature and the calculated combustion efficiency. Tuning a burner on those numbers instead of by eye saves fuel and cuts emissions, and the carbon monoxide figure is also the safety check that tells you combustion is complete and the appliance is venting properly.

Calibration gas and regulators

Measures: Certified gas concentrations

Every gas detector needs certified gas of a known concentration to be checked against, and the gas is as much a part of the system as the detector. We supply calibration gas cylinders, fixed-flow and demand-flow regulators, tubing and the adaptors that fit your instruments. A bump test before each use, using that gas, confirms the sensor responds and the alarm sounds; it is not a calibration, but it is what catches a dead sensor before someone relies on it.

Dataloggers


A spot reading tells you about one moment. A logger tells you what actually happened: the overnight excursion, the slow drift, the twenty minutes the door was open. It is the difference between an opinion and evidence.

Temperature and humidity loggers

Measures: Temperature · Relative humidity · Dew point

The most common loggers by far. They prove cold chain compliance, document storage and transport conditions, monitor cool stores, cabinets, drying rooms and museum display cases, and settle arguments about whether a room really is too humid. Options run from single-use tags that travel with a shipment through to reusable units with plug-in probes and an alarm output.

Pressure and process loggers

Measures: Pressure · 4–20 mA · Voltage · Pulse

Pressure loggers record water main and system pressure over days or weeks, which is how leaks, surges and night-time pressure problems are found. Process loggers accept the standard instrument signals, 4–20 mA, voltage and pulse inputs, so any transmitter you already have can be recorded without touching the control system.

Universal input and multi-channel loggers

Measures: Thermocouple · RTD · Voltage · Current · Pulse

A universal input logger takes thermocouples, RTDs, voltage, current and pulse signals on the same unit, with each channel configured separately. That is what you want for trials, commissioning, fault-finding and any job where you do not yet know which measurement will turn out to matter.

Wireless and networked logging

Measures: Temperature · Humidity · Process signals

Wireless loggers send their readings to a gateway or to the cloud, so data arrives without anyone walking around with a laptop and an alarm can reach a phone while there is still time to act. For monitoring that has to be continuous, such as vaccine fridges, cool stores and server rooms, this is the practical difference between finding out now and finding out at the next download.

Water, air, sound and light


Workplace and environmental measurements share a characteristic: the number usually has to stand up to someone else’s scrutiny, whether that is a regulator, a client or a council.

Water quality

Measures: pH · Conductivity · Dissolved oxygen · Turbidity · ORP

pH measures how acidic or alkaline a solution is on a scale of 0 to 14, using a glass electrode against a reference and correcting for temperature. Conductivity measures the solution’s ability to carry a current, which indicates dissolved salts and is the usual check on water purity and on cleaning solutions. Dissolved oxygen matters in aquaculture, wastewater aeration and waterway monitoring. Turbidity measures cloudiness from suspended particles. ORP, or redox, shows how actively a solution can oxidise, which is how disinfection with chlorine or ozone is confirmed.

These come as handheld meters in-line, installed probes for spot checks and field work, and pH and conductivity electrodes need regular buffer calibration and eventual replacement.

Air quality

Measures: Carbon dioxide · Particulates · Temperature · Humidity

Indoor air quality monitoring is mostly about carbon dioxide, because CO₂ is a reliable proxy for how well a space is being ventilated with outside air. Levels climbing well above outdoor background mean the ventilation is not keeping up with the number of people in the room. Monitors combining CO₂ with temperature, humidity and particulate measurement are used in classrooms, offices, gyms and meeting rooms.

Sound level meters

Measures: Sound pressure level (dB)

A sound level meter measures sound pressure level in decibels, almost always with A-weighting applied, which adjusts the reading to match how human hearing responds across frequencies. Noise exposure at work is assessed over time rather than at an instant, so meters and noise dosimeters that log over a shift are what is needed for a workplace assessment.

Light measurement

Measures: Illuminance (lux) · UV

A light meter measures illuminance in lux, corrected to the sensitivity of the human eye. It is used to check lighting levels against workplace and task requirements, to set up horticultural and growth lighting, and to verify lighting after an installation or upgrade. UV meters measure ultraviolet intensity for curing, disinfection and exposure checks.

Calibrators and test equipment


These are the instruments used to check other instruments: on the bench, in the panel or out on the plant.

Process and loop calibrators

Measures: 4–20 mA · Voltage · Thermocouple · RTD · Frequency

A process calibrator both sources and measures the standard instrument signals. Sourcing lets you inject a known 4–20 mA, voltage, thermocouple or RTD signal into a loop to prove that the controller, indicator, recorder and final element all respond correctly, without waiting for the process to move. While simultaneously Measuring lets you read what a transmitter is actually putting out. Between the two, most loop faults are found in minutes rather than by substitution.

Test equipment

Measures: Electrical · Thickness · Physical properties

We also stock general test instruments used alongside the range, including multimeters and clamp meters, thickness gauges and other portable test tools. If you are not sure what suits your application, our team will go through it with you.

Calibration and certification

Our laboratory is accredited by IANZ to ISO/IEC 17025 for pressure, temperature, infrared and humidity calibration. Working with Teltherm Instruments Ltd, we also offer service, repair, calibration and IANZ certification of gas detectors. We keep a reminder system so you know when each instrument is next due. See Calibration Lab for more.

Choosing monitoring equipment


Start with what the reading is for, because a number kept for evidence has different requirements from a number used to make a decision on the spot.

What we will ask you

  • what you need to detect or record, and at what levels it matters
  • whether it protects a person, an area, a product or a process
  • whether you need an instant reading, a continuous record, or an alarm
  • the environment: temperature, humidity, dust, water and anything that could poison a sensor
  • whether the result has to satisfy a standard, an auditor or a regulator
  • hazardous area and certification requirements.

Which instrument for which question?

What you need to know Instrument Notes
Is this space safe to enter? Portable multi-gas detector Bump test before each use
Is there a leak in this plant room? Fixed gas detector and controller Detector height follows the gas
Are there solvent vapours present? PID gas detector Broad response, not specific
Is this burner running efficiently? Flue gas analyser Also checks carbon monoxide.
Did the cool store hold temperature? Temperature datalogger Single-use or reusable
Is the humidity damaging the product? Temperature and humidity logger Records dew point too
What is the water main doing at night? Pressure datalogger Finds leaks and surges, hydrostatic pipe tests
Is this water fit for its purpose? pH, conductivity or DO meter Electrodes need calibration
Is this room ventilated well enough? CO₂ air quality monitor CO₂ indicates fresh air supply
Is the noise level a risk to hearing? Sound level meter or dosimeter Assessed over a shift
Is the lighting adequate? Light meter (lux) Compare against task requirements
Is this 4–20 mA loop working? Process or loop calibrator Sources and measures signals and fault find

Frequently asked questions


What is the difference between a bump test and a calibration?

A bump test applies a small amount of gas to confirm the detector responds and alarms. It takes under a minute and should be done before each use. A calibration uses certified gas of a known concentration to adjust the readings so they are accurate, and produces a certificate.

How often should gas detectors be calibrated?

Every six months is the usual interval, with a bump test before each use. Calibrate sooner if the detector has been exposed to high gas concentrations, dropped, or to anything that could poison the sensor, such as silicones on a catalytic bead sensor.

Which detector do I need for solvents?

A photoionisation detector. It responds to a very wide range of volatile organic compounds at low concentrations. It is not selective, so it reports a total reading, and a correction factor is applied if you need to report a specific compound.

Do single-use temperature loggers need calibration?

They are supplied calibrated and are designed to be used once, typically travelling with a shipment. Reusable loggers should be calibrated on a regular interval like any other instrument, particularly where the records are used for compliance.

What CO₂ level means a room is poorly ventilated?

Outdoor air sits at roughly 400 ppm, and indoor levels rise above that as people breathe. A reading that climbs steadily well above outdoor background while a room is occupied indicates the ventilation is not keeping up. Check the level you are required to work to for your building type.

Can you supply the calibration gas as well as the detector?

Yes. We supply calibration gas cylinders, regulators, tubing and adaptors alongside the detectors, so the gas matches the sensor and the fitting matches your instrument.

Shop our analytics range

Gas detectors, calibration gas, combustion analysers, dataloggers, water and air quality meters, sound and light meters and process calibrators.

View Analytics →
ISO 9001
Quality certified
IANZ accredited
Calibration support
Established expertise
Instrumentation specialists
NZ-based support
Technical product assistance


Not sure what you need to measure?

Tell us what you are trying to find out, and our team will recommend the right instrument.



    03 358 8309